User Tools

Site Tools


implementation:quality:qc_screens

4. Quality Capture screens

The translated parameter name defined on the ‘Display Transition’ field is displayed as the title of the screen.

If a test template contains multiple parameters, the sequence of the parameters is the same as the sequence of the parameters on the grid of the Quality Test Template form.

4.1. String

Enter the string to the input field. You can use the on-screen keyboard to enter the value.

The default value is the Default Value defined on the Quality Test Template form for the parameter. If there is no default value, the field is empty by default.

4.2. Numeric (Float and Integer)

Enter the quantity with the +/- buttons or with the numeric keypad.

In the case of ‘Float’ type parameters, the added value depends on the number of the Decimals defined for the parameter on the Quality Test Template form. Eg.: If the Decimal value is 2 for the parameter, then the added value will be 0.01. If there is an UoM specified for the parameter, it is displayed under the quantity field.

The default value is the Default Value defined on the Quality Test Template form for the parameter. If there is no default value defined, 1 is displayed by default.

Please note: It is possible to enter values outside the Min Entry – Max Entry range.

4.3. Date

Enter the date to the respective field. By default, the system displays the current date.

4.4. Valid Value

Every valid value defined for the parameter is listed on the screen. Valid values are listed in the same sequence as they were defined for the parameter on the Quality Parameters form.

To select a value, press on the line of the value. It is also possible to select a value with the up and down arrows of the keyboard. The selected value is highlighted with blue. The value set as Default Value on the Quality Test Template form is selected by default. If no value is set as default on the Quality Test Template form, then the valid value marked as Default on the Quality Parameters form is selected by default. If there is no default value set on either form, the first value listed on the Quality Parameters grid is selected by default.

When the list is too long to be displayed on one screen, use the green up and down arrows to scroll through the list. It is possible to filter the list. Enter text to the filter field, and the system only lists elements whose name includes the text that has been entered.

implementation/quality/qc_screens.txt · Last modified: 2018/07/19 14:06 by csuhaa